Kyoritsu Digital Multimeters 1062 / 1062 price in Pakistan
High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz
• True-RMS or MEAN value detection mode can be selected
• Fast Peak Hold response time of 250µs
• Low-pass filter for motor drive measurements
• Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current
• User calibration function
Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V, CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC
Reliable support for data management
• Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
Detection mode | MEAN/RMS (switch) |
---|---|
DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]) ±0.02%rdg±2dgt (Basic accuracy) |
AC V [RMS] | 50.000/500.00mV/5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) ±0.4%rdg±30dgt (Basic accuracy) |
AC V [MEAN] | 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V (Input impedance:11MΩ<50pF [50/500mV/5V],10MΩ<50pF [50/500/1000V]) ±1%rdg±30dgt (Basic accuracy) |
DCV+ACV | 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V]) ±0.5%rdg±10dgt (Basic accuracy) |
DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±0.2%rdg±5dgt (Basic accuracy) |
AC A [RMS] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±0.75%rdg±20dgt (Basic accuracy) |
AC A [MEAN] | 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A ±1.5%rdg±20dgt (Basic accuracy) |
DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±1%rdg±10dgt (Basic accuracy) |
Ω | 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ ±0.05%rdg±2dgt (Basic accuracy) |
LowPower-Ω | 5.000/50.00/500.0kΩ/5.000MΩ ±0.2%rdg±3dgt (Basic accuracy) |
Continuity buzzer | 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω) |
Diode test | 2.4000V ±1%rdg±2dgt Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current) |
Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF ±1%rdg±5dgt (Basic accuracy) |
Frequency | 2.000 - 9.999/9.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz ±0.02%rdg±1dgt (Basic accuracy) |
DUTY | 10 - 90% ±1%rdg |
Temperature | -200 - 1372ºC ±1%rdg±1.5ºC -328 - 2501.6ºF ±1%rdg±2.0ºF (with the use of K-type Temperature probe) |
Measurement functions | DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω |
Other functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight |
Applicable standards | IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC) |
Power source | R6 (1.5V)×4 (Auto power off: approx. 20 minutes) |
Dimensions | 192(L)×90(W)×49(D) mm |
Weight | Approx. 560g (including batteries) |
Included Accessories | 7220A (Test leads), R6×4, Instruction manual, 8926 (Fuse [440mA/1000V])×1 (included) 8927 (Fuse [10A/1000V])×1 (included) |